HOBO UX120-014M 4-Channel Thermocouple Data Logger
HOBO

HOBO UX120-014M 4-Channel Thermocouple Data Logger

Overview

Data logger termokopel empat kanal berlayar LCD untuk mengukur dan merekam suhu pada rentang lebar (−260 sampai 1.820°C), dengan sensor internal untuk suhu ruang.

Fitur Utama

  • Menerima hingga empat probe termokopel tipe J, K, T, E, R, S, B, atau N
  • Sensor suhu internal untuk mencatat suhu lingkungan
  • Layar LCD memastikan logger bekerja dan menampilkan status baterai
  • Pembacaan suhu terkini serta statistik minimum, maksimum, rata-rata, dan simpangan baku
  • Alarm di layar saat suhu melewati batas atas atau bawah
  • Memori 1,9 juta pengukuran dan firmware yang dapat diperbarui pengguna
Merk
HOBO
Kategori
Multi-Channel & Event Logger

Spesifikasi & Penerapan

Aplikasi
Commercial Building Environment

Detail Produk

Specification Value
Thermocouple (probes sold separately)
Type J -210° to 760°C; ±0.6°C ± probe accuracy; resolution 0.03°C
Type K -260° to 1,370°C; ±0.7°C ± probe accuracy; resolution 0.04°C
Type T -260° to 400°C; ±0.6°C ± probe accuracy; resolution 0.02°C
Type E -260° to 950°C; ±0.6°C ± probe accuracy; resolution 0.03°C
Type R -50° to 1,550°C; ±2.2°C ± probe accuracy; resolution 0.08°C
Type S -50° to 1,720°C; ±2.2°C ± probe accuracy; resolution 0.08°C
Type B 60° to 1,820°C; ±2.5°C ± probe accuracy; resolution 0.1°C
Type N -260° to 1,300°C; ±1.0°C ± probe accuracy; resolution 0.06°C
Internal Temperature
Range -20° to 70°C
Accuracy ±0.21°C from 0° to 50°C
Resolution 0.024°C at 25°C
Drift <0.1°C per year
Logger
Logging Rate 1 second to 18 hours, 12 minutes, 15 seconds
Logging Modes Normal, burst, statistics
Memory Modes Wrap when full or stop when full
Time Accuracy ±1 minute per month at 25°C
Battery 2 AAA, user replaceable; 1 year typical (1-minute logging, sampling 15 seconds or greater)
Memory 1.9 million measurements
Dimensions 10.8 x 5.41 x 2.54 cm
Operating Range Logging: -20° to 70°C; 0 to 95% RH (non-condensing)